I.C.E.M. Snc di Marchetti Giulio & Mario - Via Dei Mille, 99/105i 24060 Castelli Calepio (Bg) Italy - Cod.Fisc. E Part IVA 01634680167

Created by www.icemsnc.it - All rights reserved

Site search

Simplex

Technical features
Conductor
Red copper wire, annealed, not tinned
Insulation
Polyvinylchloride
Rated voltage Uo/U
450/750V
Working temperature
70°C on conductor if installed in ordinary environments
50°C in fire-risk environments
Max. Temperature in case of short circuit
160°C on the conductor (maximum duration 5 seconds)
Minimum bending radius
Mobile installation: 4 times the outer diameter
Maximum laying stress
15N for mm² of copper total section
Standard sheath colour
Black
Standard marking
Simplex cable + mm² + CE + year + lot.
Distance between markings
Every 20/25cm. about
Means of marking
Inkjet
Nominal cross sectional area of conductor
Maximum diameter of wire of conductor
Thickness of covering
Mean overall diameter
Maximum conductor resistance at 20°C
Capacity of conductor at 60% duty cycle
Capacity of conductor at 35% duty cycle
mmq
mm
mm
mm
Ohm/Km
Ampère
Ampère
10
0,31
1,6
6,7
1,91
108
122
16
0,31
1,8
8,2
1,21
175
230
25
0,31
2
10,2
0,78
230
300
35
0,31
2,2
11,6
0,554
290
375
50
0,31
2,4
13,6
0,386
365
480
70
0,31
2,6
15,6
0,272
460
600
95
0,31
2,8
18,2
0,206
560
730
120
0,31
3
20,4
0,161
650
850
150
0,31
3,3
24,7
0,129
750
980
185
0,31
3,5
25,7
0,106
860
1120
Applications

Versione italiana

Cavo per saldatura flessibile in pvc Simplex ICEM - HOME Company Location Products Contacts News & events Technical & Quality area
Flexible cable
Fire performance
Lighting
Industry
Electromechanics
Power installation
Resistant to chemicals
Panel wiring
Household appliances
Underground conduit installation
Indoor protected installation
Legend:
Scheda tecnica Simplex - Data sheet Simplex.pdf

Data sheet

The data and technical features shown in this page are not binding and can be amended as a consequence of modifications and/or improvements deemed necessary by the manufacturer.